Product Features
·Shanghai Shuni Industrial Chiller Series incorporates internationally renowned brands such as Copeland, Danfoss, Panasonic, and Daikin compressors, encompassing scroll, piston, screw, semi-hermetic, and fully hermetic types. The entire unit is equipped with high-efficiency copper tube fins and industrial stainless steel condensers and evaporators, with materials meeting the highest industrial food-grade standards.
·Electrical components are sourced from world-class brands including Siemens, Schneider, and ABB, ensuring reliable quality and exceptional performance. This enables Shuni chillers to deliver advantages such as compact size, low noise, high capacity, extended lifespan, and user-friendly operation. Multiple refrigerants are available—besides R22, environmentally friendly options like R134a and R407c can be selected to meet low-temperature and specialized environmental requirements.
·The chiller control system employs Shuni's proprietary high-precision main control panel, PLC programmable controller, and human-machine interface with full Chinese display. This enables fully automated computer-regulated control throughout the entire process, ensuring precise and reliable operation.
·Sunny chillers feature a compact structure with a small footprint, lightweight design, and easy portability. They operate smoothly and safely with minimal vibration, requiring no complex foundations for straightforward installation. Automatic protection functions include: high/low pressure protection, compressor protection, motor overload and overheat protection, freeze protection, chilled water/cooling water flow failure protection, temperature-sensitive fusible plugs, and safety valves.
| Technical parameters of air cooled normal temperature unit |
| Model |
|
SCA-01 |
SCA-02 |
SCA-03 |
SCA-04 |
SCA-05 |
SCA-06 |
SCA-08 |
SCA-10 |
SCA-12 |
SCA-15 |
SCA-20 |
SCA-25 |
SCA-30 |
SCA-40 |
SCA-50 |
SCA-60 |
| Cooling capacity |
KW |
2.7 |
5.4 |
8.5 |
11.9 |
15 |
18 |
21.5 |
30 |
38 |
46.1 |
62.2 |
70.4 |
93.3 |
124.4 |
140.8 |
176 |
| 103kcal/h |
2.4 |
4.6 |
7.3 |
10.2 |
12.9 |
15.5 |
18.5 |
25.8 |
32.7 |
39.6 |
53.4 |
60.5 |
80.2 |
106.9 |
121 |
151.3 |
| Power Supply |
V/ph/Hz |
220/1/50 |
380/3/50 |
380/3/50 |
| Input Power |
kw |
1.34 |
2.19 |
3.19 |
4.73 |
5.23 |
6.13 |
7.76 |
10.54 |
12.34 |
15.6 |
20.1 |
24.1 |
29.05 |
39.55 |
49.2 |
56.6 |
| Compressor Type |
|
Rotor |
Scroll |
Scroll |
| Compressor Power |
kw |
0.88 |
1.69 |
2.45 |
3.8 |
4.3 |
5.2 |
6.2 |
8.6 |
10.4 |
12.3 |
16.2 |
20.2 |
24.3 |
32.4 |
40.4 |
50.5 |
| Pump Power |
kw |
0.37 |
0.37 |
0.55 |
0.55 |
0.55 |
0.55 |
1.1 |
1.1 |
1.1 |
2.2 |
2.2 |
2.2 |
3.75 |
3.75 |
4 |
5.5 |
| Pump Head |
m |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
| Chilled Water Flow |
m3/h |
0.46 |
0.92 |
1.55 |
2 |
2.5 |
3.1 |
4 |
5 |
6.5 |
7.6 |
10.2 |
11.6 |
15.5 |
21.1 |
26.7 |
29.8 |
| Evaporator Type |
|
Water Tank Type/Stainless Steel Plate Type |
Water Tank Type/Stainless Steel Plate Type |
| Water Tank Volume |
L |
20 |
40 |
50 |
70 |
70 |
80 |
120 |
200 |
200 |
270 |
350 |
350 |
420 |
500 |
600 |
650 |
| Pipe Size |
DN |
15 |
20 |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
50 |
50 |
50 |
65 |
80 |
80 |
80 |
| Condenser |
|
Coil |
Coil |
| Air Volume |
m3/h |
1500 |
2800 |
4000 |
6500 |
6800 |
7500 |
9300 |
12000 |
13000 |
16000 |
20000 |
24000 |
29000 |
40000 |
48000 |
60000 |
| Fan power |
W |
90 |
130 |
190 |
380 |
380 |
380 |
460 |
840 |
840 |
1100 |
1700 |
1700 |
2550 |
3400 |
3900 |
4200 |
| Refrigerant |
|
R22/R134a/R404 |
R22/R134a/R404 |
| Throttle Mode |
|
Capillary Tube/Expansion Valve |
Expansion Valve |
| Protector |
|
Pressure, Overload, Anti-freeze, Delay, Over-temperature, Water Flow |
| Noise Level |
dB(A) |
58 |
59 |
60 |
62 |
62 |
62 |
64 |
65 |
65 |
67 |
68 |
68 |
68 |
68 |
68 |
68 |
| Weight |
Kg |
75 |
120 |
150 |
180 |
180 |
200 |
230 |
260 |
350 |
650 |
750 |
1200 |
1300 |
1500 |
1800 |
2100 |
| Dimension |
L |
mm |
600 |
600 |
1000 |
1200 |
1200 |
1250 |
1450 |
1650 |
1650 |
1850 |
2000 |
2150 |
2600 |
3300 |
3300 |
4100 |
| W |
mm |
520 |
600 |
550 |
600 |
600 |
650 |
750 |
790 |
790 |
900 |
950 |
1000 |
1100 |
1500 |
1500 |
1500 |
| H |
mm |
800 |
1000 |
1050 |
1100 |
1100 |
1200 |
1200 |
1300 |
1300 |
1650 |
1650 |
1700 |
1700 |
1600 |
1600 |
1600 |
Directions: 1. The cooling capacity is based on a 35℃ ambient temperature, a 12℃ entering water temperature, and a 7℃ leaving water temperature. 2. Design and specifications are subject to change without prior notice. 3. The above parameters apply to standard products. If you require increased cooling capacity or customized products, please contact us.
|
| Technical parameters of air cooled low temperature unit (-5℃) |
| Model |
|
SCA03L |
SCA04L |
SCA05L |
SCA06L |
SCA08L |
SCA10L |
SCA12L |
SCA15L |
SCA20L |
SCA25L |
SCA30L |
SCA40L |
SCA50L |
SCA60L |
| Cooling capacity |
KW |
6.2 |
7.7 |
9.95 |
12.4 |
15.4 |
19 |
24.8 |
31.6 |
43.4 |
49.8 |
65.1 |
86.8 |
99.6 |
124.5 |
| 103kcal/h |
5.3 |
6.6 |
8.5 |
10.6 |
13.2 |
16.3 |
21.3 |
27.1 |
37.3 |
42.8 |
55.9 |
74.6 |
85.6 |
107 |
| Power Supply |
V/ph/Hz |
380/3/50 |
380/3/50 |
| Input Power |
kw |
2.74 |
3.63 |
4.03 |
4.73 |
6.96 |
8.24 |
9.54 |
12.8 |
16.6 |
18.3 |
25.3 |
29.4 |
33.1 |
41.9 |
| Compressor Type |
|
Scroll |
Scroll |
| Compressor Power |
kw |
2 |
2.7 |
3.1 |
3.8 |
5.4 |
6.3 |
7.6 |
9.5 |
12.7 |
14.4 |
19 |
25.4 |
28.8 |
36 |
| Pump Power |
kw |
0.55 |
0.55 |
0.55 |
0.55 |
1.1 |
1.1 |
1.1 |
2.2 |
2.2 |
2.2 |
3.75 |
3.75 |
4 |
5.5 |
| Pump Head |
m |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
| Chilled Water Flow |
m³/h |
1.55 |
2 |
2.5 |
3.1 |
4 |
5 |
6.5 |
7.6 |
10.2 |
11.6 |
15.5 |
21.1 |
26.7 |
29.8 |
| Evaporator Type |
|
Water Tank Type/Stainless Steel Plate Type |
Water Tank Type/Stainless Steel Plate Type |
| Water Tank Volume |
L |
50 |
70 |
70 |
80 |
120 |
200 |
200 |
270 |
350 |
350 |
420 |
500 |
600 |
650 |
| Pipe Size |
DN |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
50 |
50 |
50 |
50 |
65 |
65 |
65 |
| Condenser |
|
Coil |
Coil |
| Air Volume |
m³/h |
4000 |
6500 |
6800 |
7500 |
9300 |
12000 |
13000 |
16000 |
20000 |
24000 |
29000 |
40000 |
48000 |
60000 |
| Fan power |
W |
190 |
380 |
380 |
380 |
460 |
840 |
840 |
1100 |
1700 |
1700 |
2550 |
3400 |
3900 |
4200 |
| Refrigerant |
|
R22 |
R22 |
| Throttle Mode |
|
Capillary Tube/Expansion Valve |
Expansion Valve |
| Protector |
|
Pressure, Overload, Anti-freeze, Delay, Over-temperature, Water Flow |
| Noise Level |
dB(A) |
60 |
62 |
62 |
62 |
64 |
65 |
65 |
67 |
68 |
68 |
68 |
68 |
68 |
68 |
| Weight |
Kg |
180 |
210 |
210 |
250 |
280 |
300 |
400 |
780 |
900 |
1300 |
1450 |
1700 |
2000 |
2400 |
| Dimension |
L |
mm |
1000 |
1200 |
1200 |
1250 |
1450 |
1650 |
1650 |
1850 |
2000 |
2150 |
2600 |
3300 |
3300 |
4100 |
| W |
mm |
550 |
600 |
600 |
650 |
750 |
790 |
790 |
900 |
950 |
1000 |
1100 |
1500 |
1500 |
1500 |
| H |
mm |
1050 |
1100 |
1100 |
1200 |
1200 |
1300 |
1300 |
1650 |
1650 |
1700 |
1700 |
1600 |
1600 |
1600 |
Directions: 1. The cooling capacity is based on a 35℃ ambient temperature, a 0℃ entering water temperature and a -5℃ leaving water temperature. 2. Design and specification are subject to change without prior notice. 3. The above parameters are standard products. If you need more cooling or customized products, please contact us. |
| Technical parameters of air cooled low temperature unit(-10℃) |
| Model |
|
SCA-3LH |
SCA-4LH |
SCA-5LH |
SCA-6LH |
SCA-8LH |
SCA-10LH |
SCA-12LH |
SCA-15LH |
SCA-20LH |
SCA-25LH |
SCA30LH |
SCA40LH |
SCA50LH |
SCA60LH |
| Cooling capacity |
KW |
5.5 |
6.2 |
9.3 |
10.9 |
12.4 |
18.6 |
21.8 |
28.7 |
38.8 |
46 |
58.2 |
77.6 |
92 |
115 |
| 103kcal/h |
4.7 |
5.3 |
7.9 |
9.3 |
10.6 |
15.9 |
18.7 |
24.6 |
33.3 |
39.5 |
50 |
66.7 |
79 |
98.9 |
| Power Supply |
V/ph/Hz |
380/3/50 |
380/3/50 |
| Input Power |
kw |
2.9 |
3.8 |
4.6 |
5.2 |
7.5 |
9.3 |
10.5 |
14.4 |
18.9 |
22.6 |
28.6 |
36.9 |
45.3 |
56.4 |
| Compressor Type |
|
Scroll |
Scroll |
| Compressor Power |
kw |
2.2 |
2.9 |
3.7 |
4.3 |
6 |
7.4 |
8.6 |
11.1 |
15 |
18.7 |
22.3 |
29.8 |
37.4 |
46.7 |
| Pump Power |
kw |
0.55 |
0.55 |
0.55 |
0.55 |
1.1 |
1.1 |
1.1 |
2.2 |
2.2 |
2.2 |
3.75 |
3.75 |
4 |
5.5 |
| Pump Head |
m |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
| Chilled Water Flow |
m³/h |
1.55 |
2 |
2.5 |
3.1 |
4 |
5 |
6.5 |
7.6 |
10.2 |
11.6 |
15.5 |
21.1 |
26.7 |
29.8 |
| Evaporator Type |
|
Water Tank Type/Stainless Steel Plate Type |
Water Tank Type/Stainless Steel Plate Type |
| Water Tank Volume |
L |
50 |
70 |
70 |
80 |
120 |
200 |
200 |
270 |
350 |
350 |
420 |
500 |
600 |
650 |
| Pipe Size |
DN |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
40 |
50 |
50 |
50 |
65 |
65 |
65 |
| Condenser |
|
Coil |
Coil |
| Air Volume |
m³/h |
4000 |
6500 |
6800 |
7500 |
9300 |
12000 |
13000 |
16000 |
20000 |
24000 |
29000 |
40000 |
48000 |
60000 |
| Fan power |
W |
190 |
380 |
380 |
380 |
460 |
840 |
840 |
1100 |
1700 |
1700 |
2550 |
3400 |
3900 |
4200 |
| Refrigerant |
|
R404a |
R404a |
| Throttle Mode |
|
Capillary Tube/Expansion Valve |
Expansion Valve |
| Protector |
|
Pressure, Overload, Anti-freeze, Delay, Over-temperature, Water Flow |
| Noise Level |
dB(A) |
60 |
62 |
62 |
62 |
64 |
65 |
65 |
67 |
68 |
68 |
68 |
68 |
68 |
68 |
| Weight |
Kg |
200 |
230 |
250 |
280 |
320 |
350 |
450 |
820 |
980 |
1400 |
1600 |
1850 |
2200 |
2600 |
| Dimension |
L |
mm |
1000 |
1200 |
1200 |
1250 |
1450 |
1650 |
1650 |
1850 |
2000 |
2150 |
2600 |
3300 |
3300 |
4100 |
| W |
mm |
550 |
600 |
600 |
650 |
750 |
790 |
790 |
900 |
950 |
1000 |
1100 |
1500 |
1500 |
1500 |
| H |
mm |
1050 |
1100 |
1100 |
1200 |
1200 |
1300 |
1300 |
1650 |
1650 |
1700 |
1700 |
1600 |
1600 |
1600 |
Directions: 1. The cooling capacity is based on a 35℃ ambient temperature, a -5℃ entering water temperature and a -10℃ leaving water temperature. 2. Design and specification are subject to change without prior notice. 3. The above parameters are standard products. If you need more cooling or customized products, please contact us. |
| Technical parameters of air cooled low temperature unit(-20℃) |
| Model |
|
SCA-3CH |
SCA -4CH |
SCA-5CH |
SCA-6CH |
SCA-8CH |
SCA-10CH |
SCA-12CH |
SCA-15CH |
SCA-20CH |
SCA-25CH |
SCA-30CH |
SCA-40CH |
SCA-50CH |
SCA-60CH |
| Cooling capacity |
KW |
3.7 |
5 |
6.2 |
7.4 |
10 |
12.5 |
14.8 |
19.5 |
26.6 |
31.6 |
39.9 |
53.2 |
63.2 |
79 |
| 103kcal/h |
3.1 |
4.3 |
5.3 |
6.3 |
8.6 |
10.7 |
12.7 |
16.7 |
22.8 |
27.1 |
34.3 |
45.7 |
54.3 |
67.9 |
| Power Supply |
V/ph/Hz |
380/3/50 |
380/3/50 |
| Input Power |
kw |
2.7 |
3.7 |
4.4 |
5.2 |
7.2 |
8.9 |
10.1 |
13.3 |
17.4 |
21.7 |
26.6 |
36.3 |
43.2 |
52.7 |
| Compressor Type |
|
Scroll |
Scroll |
| Compressor Power |
kw |
2.2 |
3 |
3.7 |
4.3 |
6 |
7.4 |
8.6 |
11.1 |
14.6 |
17.8 |
21.9 |
29.2 |
35.6 |
44.5 |
| Pump Power |
kw |
0.37 |
0.37 |
0.37 |
0.55 |
0.75 |
0.75 |
0.75 |
1.1 |
1.1 |
2.2 |
2.2 |
3.75 |
3.75 |
4 |
| Pump Head |
m |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
250 |
20 |
| Chilled Water Flow |
m³/h |
1.55 |
2 |
2.5 |
3.1 |
4 |
5 |
6.5 |
7.6 |
10.2 |
11.6 |
15.5 |
21.1 |
26.7 |
29.8 |
| Evaporator Type |
|
Water Tank Type/Stainless Steel Plate Type |
Water Tank Type/Stainless Steel Plate Type |
| Water Tank Volume |
L |
50 |
70 |
70 |
90 |
120 |
200 |
200 |
270 |
350 |
350 |
420 |
500 |
600 |
650 |
| Pipe Size |
DN |
20 |
20 |
20 |
25 |
25 |
25 |
25 |
40 |
40 |
50 |
50 |
65 |
65 |
65 |
| Condenser |
|
Coil |
Coil |
| Air Volume |
m³/h |
4000 |
6500 |
6800 |
7500 |
9300 |
12000 |
13000 |
16000 |
20000 |
24000 |
29000 |
40000 |
48000 |
60000 |
| Fan power |
W |
190 |
380 |
380 |
380 |
460 |
840 |
840 |
1100 |
1700 |
1700 |
2550 |
3400 |
3900 |
4200 |
| Refrigerant |
|
R22 |
R22 |
| Throttle Mode |
|
Capillary Tube/Expansion Valve |
Expansion Valve |
| Protector |
|
Pressure, Overload, Anti-freeze, Delay, Over-temperature, Water Flow |
| Noise Level |
dB(A) |
60 |
62 |
62 |
64 |
65 |
66 |
66 |
67 |
68 |
68 |
68 |
68 |
68 |
68 |
| Weight |
Kg |
200 |
230 |
250 |
280 |
320 |
350 |
450 |
820 |
980 |
1400 |
1600 |
1850 |
2200 |
2600 |
| Dimension |
L |
mm |
1000 |
1200 |
1200 |
1250 |
1450 |
1650 |
1650 |
1850 |
2000 |
2150 |
2600 |
3300 |
3300 |
4100 |
| W |
mm |
550 |
600 |
600 |
650 |
750 |
790 |
790 |
900 |
950 |
1000 |
1100 |
1500 |
1500 |
1500 |
| H |
mm |
1050 |
1100 |
1100 |
1200 |
1200 |
1300 |
1300 |
1650 |
1650 |
1700 |
1700 |
1600 |
1600 |
1600 |
Directions: 1. The cooling capacity is based on a 35℃ ambient temperature, a -15℃ entering water temperature and a -20℃ leaving water temperature. 2. Design and specification are subject to change without prior notice. 3. The above parameters are standard products. If you need more cooling or customized products, please contact us. |