Air Cooled Chiller with Hydraulic Pump

Integrated hydraulic module with air-cooled condenser · 50kW-180kW · Factory-tested water circuit

95 kW Cooling at 25°C water
280 L/min Pump flow at 0.40 MPa
400 L Buffer tank capacity
Reference unit
Capacity at 25°C95 kW
Capacity at 15°C79 kW
Compressor2 × scroll, tandem
CondenserAir-cooled, EC fans
PumpCentrifugal, integrated
Tank400 L, insulated
RefrigerantR410A, 26 kg
Power supply400V, 3-phase, 50Hz
Hydraulic module Integrated pump, buffer tank, Y-strainer, flow switch, fill and drain points, and pressure gauges on the unit frame. Factory assembled and pressure tested with the water circuit complete before delivery.
Compliance CE marked under LVD 2014/35/EU and EMC 2014/30/EU. Refrigerant data sheet per EN 378. RoHS 2 compliant. Declaration of conformity supplied with each unit.

This air cooled chiller with hydraulic pump is supplied as an integrated unit combining the refrigeration circuit, air-cooled condenser, circulation pump, and buffer tank on a single frame. The arrangement is intended for installations where the cooling equipment must be a self-contained package: the plant room contains the chiller, and the complete water circuit is already assembled and tested rather than being built up on site from separate components.

The configuration suits process cooling where a buffer volume is required to absorb load variation, and where the water circuit is not part of an existing central plant with its own pumps. Site work reduces to positioning the unit, connecting supply and return water lines, and making the power connection.

Integrated Hydraulic Circuit

Circulation pump Centrifugal pump with mechanical seal, mounted on the frame and wired to the control panel. Flow 280 L/min at 0.40 MPa. High-head option available where the circuit requires greater pressure.
Buffer tank 400 L insulated tank with fill, drain, and vent points on the unit exterior, plus level sight glass. Buffer volume absorbs load swings and reduces compressor cycling.
Strainer and flow switch Y-strainer on the pump suction with a serviceable element. Flow switch interlocked to the compressor, so cooling cannot run without confirmed flow. Both accessible from the front panel.
Air-cooled condenser Condenser coil with EC fans mounted on the unit frame. Fan speed controlled from head pressure. Coil face accessible from the unit exterior for cleaning without removing panels.

Commercial and Technical Advantages

Complete package, one supplier Chiller, condenser, pump, and tank supplied and tested as one unit. Performance figures for capacity, flow, and head refer to the complete assembly rather than components with interface assumptions left to the installer.
Reduced site scope Pump wiring, flow switch, and controls are complete from the factory. Site work is limited to water connections and power supply, which shortens the installation programme and removes interface risk between trades.
Factory pressure tested The water circuit is assembled and pressure tested before delivery, and the refrigeration circuit is charged and tested. Test records for both are supplied rather than being recorded for the first time on site.
Buffer volume for load variation The 400 L tank absorbs short-term load swings and reduces compressor start frequency. Where the process has batch or intermittent heat loads, the buffer is what prevents repeated cycling between start and stop.
Service access arranged on the frame Strainer element, flow switch, tank fill and drain, and pressure gauges are all accessible from the unit exterior. Routine water circuit maintenance does not require removing panels or disconnecting pipework.
Single monitoring interface Modbus RTU registers expose water temperatures, flow status, tank level, fan speed, pump status, and alarm codes from one set of registers. No need to integrate separate chiller and pump controllers.

Technical Parameters

Cooling
Capacity at 25°C water95 kW
Capacity at 15°C water79 kW
Capacity at 10°C water68 kW
Water setpoint range5°C to 20°C
Temperature stability±1.0°C
RefrigerantR410A, 26 kg
Hydraulic
Pump typeCentrifugal, mechanical seal
Pump flow280 L/min at 0.40 MPa
Buffer tank400 L, insulated
Tank material304 stainless steel
ConnectionsDN65 flange
FiltrationY-strainer, 30 mesh
Electrical and physical
Power supply400V AC, 3-phase, 50Hz
Rated current per phase172 A
Sound pressure at 5 m64 dB(A)
Operating ambient-15°C to +43°C
Dimensions (L×W×H)3100 × 1450 × 1850 mm
Net weight, dry1180 kg

Deployment Contexts

01 Process cooling without a plant room Sites where no separate plant room is available and the cooling equipment must be installed adjacent to the process with a defined footprint and a single power feed.
02 Batch and intermittent processes Moulding, extrusion, and batch mixing processes where the heat load varies through the cycle and the buffer volume prevents the compressor from cycling repeatedly.
03 Retrofit into existing circuits Facilities replacing an ageing chiller where the existing water circuit remains and the replacement must connect to the existing supply and return lines with a defined flow and head.
04 Projects with constrained site labour Installations where site labour for interconnecting separate components is limited, and where the reduced site scope of a packaged unit shortens the installation programme.

Selection and Installation Notes

Pump head against circuit The integrated pump provides 0.40 MPa at 280 L/min. Confirm that the equipment-side pressure drop plus site pipework losses remain within the available head at the required flow. Where greater head is required, specify the high-head pump at order stage.
Structural loading At 1180 kg dry and approximately 1580 kg with the tank filled, the installation position must be assessed for structural capacity. Confirm floor loading and the lifting plan before delivery. Lifting points are provided on the frame.
Airflow and heat rejection The condenser rejects the full cooling load plus compressor and pump power to the surrounding air. Ensure the installation location can dissipate this heat or provide ventilation. Maintain 600mm at the condenser inlet and 900mm at the discharge.
Water quality and freeze protection Use demineralised or softened water where local hardness exceeds 200 ppm. Where the circuit is exposed to below-zero ambient during shutdown, glycol is required and the pump and capacity should be adjusted accordingly. The unit does not protect standing water from freezing.
Power and protection A single power feed serves the chiller and pump. Dedicated 3-pole breaker sized for 172 A per phase, with cable sized accordingly. Grounding resistance ≤ 4 Ω. Confirm available supply capacity before installation.
Maintenance interval Y-strainer cleaning quarterly. Condenser coil cleaning quarterly, more frequently near trees or industrial discharge. Tank water quality check annually. Pump mechanical seal inspection every 2 years. Refrigerant charge and pressure switch verification annually.

Procurement FAQ

The hydraulic module is normally integrated with the chiller as a single package. A separate pump and tank skid can be supplied for connection to an existing chiller, where the flow and head requirements are known and the chiller has a compatible flow switch interface. Provide the existing chiller data for evaluation.

Site work is limited to positioning the unit, connecting supply and return water lines to the flanged connections, making the power connection, and filling and venting the water circuit. Pump wiring, flow switch wiring, and the interconnections between chiller and tank are completed at the factory.

Head pressure control with variable-speed EC fans is included as standard, allowing operation down to -15°C ambient. For lower ambient, the low ambient package with additional fan cycling logic and receiver sizing can be specified at order stage. Confirm the site's design minimum ambient before ordering.

Yes. A drain point is provided on the tank exterior with a hose connection. The water circuit is normally drained for transport and filled on site. For winter shutdown in unheated locations, drain the circuit or ensure glycol concentration is adequate for the lowest expected ambient.

Dimensional drawing including lifting points and maintenance clearances, wiring diagram, capacity table against water temperature, pump curve, refrigerant data sheet, Modbus register map, factory pressure test record for the water circuit, refrigeration test record, installation and commissioning checklist, and declaration of conformity under LVD and EMC directives.

Standard warranty is 24 months from commissioning or 30 months from shipment. Compressor coverage extends to 60 months. Pump mechanical seals, strainer elements, and flow switches are wear or consumable items. Service parts including compressors, EC fans, controllers, and pumps are held for a minimum of 10 years.

Product Categories

Complete Refrigeration Portfolio

Comprehensive range of industrial refrigeration equipment — standard & custom

Outdoor Cabinet AC

Weatherproof, robust cooling for outdoor enclosures & telecom shelters

IP54

Indoor Cabinet AC

Precision climate control for indoor electrical cabinets & control panels

compact

Air Cooled Chiller

Efficient air-cooled systems for plastics, laser, food & diverse industries

energy saving

Water Cooled Chiller

High-performance water-cooled industrial chillers with superior COP

high efficiency

Air Cooled Box Chiller

Compact, ready-to-use air cooled box chillers for small to medium loads

plug & play

Water Cooled Box Chiller

Space-saving water cooled box type chillers with integrated pump & tank

integrated

Integrated Chiller

All-in-one chilling solutions with smart control and remote monitoring

IoT ready

Air Cooled Screw Chiller

Heavy-duty screw compressor, air cooled — for large industrial applications

heavy duty

Water Cooled Screw Chiller

High-capacity water cooled screw chillers for continuous operation

reliable

Water Cooled Screw Evaporative Cooling Chiller

Evaporative assisted cooling for maximum efficiency in hot climates

eco

Water Heat Exchanger

Plate, shell & tube heat exchangers for various process applications

custom

Machine Room AC

Precision air conditioning for data centers, server rooms & telecom

24/7

Cooling Tower

Open & closed circuit cooling towers for industrial heat rejection

FRP

Professional Customization

Tailor-made solutions — from design to manufacturing, for your specific needs

CUSTOM
ISO 9001 · CE Certified

Shanghai Soouney Refrigeration Equipment Co., Ltd.

A large-to-medium-sized high-tech enterprise integrating R&D, production and sales. Upholding "integrity, quality, service and innovation" — delivering reliable cooling solutions to the world.

11+
Export Countries
200+
Projects Delivered
19+
Years of Innovation
100%
Client Satisfaction
Custom Solutions
2007

Engineering Excellence in Refrigeration

Shanghai Soouney was founded with a vision to become a leading force in the refrigeration industry. We are China Air Cooled Chiller with Hydraulic Pump Manufacturers and Custom Air Cooled Chiller with Hydraulic Pump Suppliers. Today, we are a renowned brand in cabinet air conditioners and industrial chillers, recognised by professionals worldwide.

Rooted in the Chinese market, we provide reliable refrigeration solutions to clients across the globe — from standard products to professional customisation.

From standard products to professional customization — we deliver precision cooling.

R&D Driven

High starting points, stringent standards — continuous innovation

Integrity & Trust

Long-term partnerships built on transparency and after-sales support

Certified Quality

ISO 9001, CE, and industry-specific approvals across all lines

Global Mindset

Serving 40+ countries with tailored refrigeration solutions

"We don't just cool equipment — we build trust, one project at a time."

Why Soouney

Driven by Quality & Innovation

Committed to delivering excellence through continuous improvement and customer-centric solutions.

R&D Focus

High starting points, stringent standards — continuous product improvement

Integrity & Service

Long-term partnerships built on trust, transparency and after-sales support

Global Presence

Rooted in China, serving worldwide with reliable refrigeration solutions

Certified Quality

ISO 9001, CE, and industry-specific approvals for all product lines

Quick Inquiry

We'll get back to you within 24 hours.