Vertical Electrical Cabinet Air Conditioner

Side-mount vertical configuration for tall electrical enclosures · IP54 · 2000W-3500W · 400V 3-phase

Enclosure rating IP54 / NEMA 12
Refrigerant R454C (GWP 148)
Mounting Side wall / vertical
Communication Modbus RTU / PROFINET
2800 W Cooling capacity at 35°C ambient
6.8 A Rated current per phase
-40°C / +55°C Operating ambient range
85 kg Net unit weight

This vertical electrical cabinet air conditioner is configured for side-wall mounting on tall enclosures, including MCC sections, drive cabinets, and power distribution panels. The unit delivers 2800W of cooling at 35°C ambient using a scroll compressor and dual-circuit condenser, providing 50% capacity redundancy if one circuit is taken offline for service.

The vertical layout positions the evaporator along the cabinet height, distributing cooled air across multiple component tiers rather than concentrating it at a single elevation. The condenser section is isolated from the evaporator air path to prevent cross-contamination in dusty plant environments.

Cooling capacity 2800 W at 35°C
Power supply 400V AC, 3-phase, 50/60Hz
Refrigerant R454C, 2 × 520 g
Airflow (evaporator) 850 m³/h
Dimensions (H×W×D) 1100 × 700 × 350 mm
Weight 85 kg

Commercial and Technical Advantages

Dual refrigeration circuits
Two independent scroll compressors and condenser coils. If one circuit faults, the remaining circuit continues at approximately 70% capacity, allowing scheduled repair without immediate cabinet shutdown.
Vertical air distribution
Evaporator positioned along the cabinet height delivers cooled air across multiple tiers of drives, breakers, and control modules, reducing hot spots at upper elevations.
Service access without removal
Filter, controller, and electrical panel accessible from the front. Refrigeration circuit service ports reachable after removing a single access cover, without dismounting the unit.
Plant network integration
Modbus RTU standard; PROFINET optional. Dry-contact alarm relay for legacy panels. Registers expose suction and discharge pressures, alarm codes, and runtime hours.
Specification compliance
CE marked under LVD 2014/35/EU and EMC 2014/30/EU. Refrigerant charge and pressure ratings documented per EN 378. RoHS 2 compliant. Test reports available on request.

Operating and Protection Parameters

Cooling and electrical

Cooling capacity at 35°C ambient2800 W ± 4%
Capacity at 45°C ambient2520 W (derated)
Operating ambient range-40°C to +55°C
Power supply400V AC, 3-phase, 50/60Hz
Rated current per phase6.8 A
Locked rotor current18.5 A
Refrigerant and chargeR454C, 2 × 520 g (A2L)
Expansion deviceElectronic expansion valve

Mechanical and protection

Enclosure ratingIP54 / NEMA 12
Casing materialGalvanized steel, 120 µm powder coat
FastenersStainless steel A2
Sound pressure at 1 m62 dB(A) at 25°C
Dimensions (H×W×D)1100 × 700 × 350 mm
Weight85 kg
Protection functionsPhase loss, phase reversal, over/under voltage, high and low pressure
CommunicationModbus RTU standard, PROFINET optional

Deployment Contexts

01
Motor control centers Tall MCC sections with drives and starters distributed across multiple tiers. Vertical airflow limits temperature stratification between upper and lower compartments.
02
Variable frequency drive cabinets Drive enclosures generating concentrated heat at the rectifier and inverter stages. Dual circuits allow one compressor to be serviced while the cabinet remains energized.
03
Power distribution and switchgear Distribution panels in utility and industrial substations where equipment availability requirements prevent extended cooling outages.
04
Process and packaging lines Control cabinets adjacent to production equipment, where high ambient temperature and dust loading require isolated condenser and evaporator air paths.

Selection and Installation Notes

Sizing Calculate total internal dissipation, add solar gain for outdoor walls, then apply a 20% margin. For sealed cabinets above 3.5 m³ with high drive content, provide cabinet dimensions and component list for a thermal calculation.
Mounting Side-wall installation with M12 bolts on a flat panel, minimum 2.0 mm steel. Reinforce panels below 2.0 mm. Maintain 350 mm clearance at the condenser inlet and 550 mm at the discharge.
Power and protection Dedicated 3-pole breaker, 16 A C-curve. Copper conductors 4 mm² per phase. Grounding resistance ≤ 2 Ω. External Type 1+2 surge protection recommended for exposed outdoor installations.
Condensate Condensate is evaporated by condenser heat in standard configurations. Where continuous high humidity exceeds 85% RH, route the optional drain kit to a collection point.
Maintenance interval Filter inspection monthly in dusty plants, otherwise quarterly. Condenser coil cleaning quarterly. Annual check of refrigerant charge, pressure switch operation, and electrical torque values.

Procurement FAQ

Each unit ships with a wiring diagram, dimensional drawing, mounting template, Modbus register map, and a declaration of conformity covering LVD and EMC directives. Refrigerant charge and pressure test records are included for EN 378 documentation.

Standard production uses R454C. R134a and R513A variants are available for regions with specific refrigerant regulations or where existing site equipment uses those refrigerants. Minimum order quantities apply for non-standard charges.

Standard configuration lead time is 4 to 6 weeks. Orders above 50 units are scheduled individually. Custom voltages, communication options, or casing finishes add 2 to 3 weeks. Contact the sales team for a production slot quotation.

Factory testing includes a circuit isolation test where each refrigeration circuit is operated independently while the other is locked out. Capacity at single-circuit operation is recorded on the test sheet and verified to be at least 70% of nominal.

Compressors, EC fans, controllers, expansion valves, and pressure switches are held as service parts for a minimum of 10 years from the date of manufacture. Consumable items such as filters and gaskets are available from stock.

Standard warranty is 24 months from commissioning or 30 months from shipment, whichever occurs first. Compressor coverage extends to 60 months. Warranty is conditional on documented maintenance per the published schedule.

Product Categories

Complete Refrigeration Portfolio

Comprehensive range of industrial refrigeration equipment — standard & custom

Outdoor Cabinet AC

Weatherproof, robust cooling for outdoor enclosures & telecom shelters

IP54

Indoor Cabinet AC

Precision climate control for indoor electrical cabinets & control panels

compact

Air Cooled Chiller

Efficient air-cooled systems for plastics, laser, food & diverse industries

energy saving

Water Cooled Chiller

High-performance water-cooled industrial chillers with superior COP

high efficiency

Air Cooled Box Chiller

Compact, ready-to-use air cooled box chillers for small to medium loads

plug & play

Water Cooled Box Chiller

Space-saving water cooled box type chillers with integrated pump & tank

integrated

Integrated Chiller

All-in-one chilling solutions with smart control and remote monitoring

IoT ready

Air Cooled Screw Chiller

Heavy-duty screw compressor, air cooled — for large industrial applications

heavy duty

Water Cooled Screw Chiller

High-capacity water cooled screw chillers for continuous operation

reliable

Water Cooled Screw Evaporative Cooling Chiller

Evaporative assisted cooling for maximum efficiency in hot climates

eco

Water Heat Exchanger

Plate, shell & tube heat exchangers for various process applications

custom

Machine Room AC

Precision air conditioning for data centers, server rooms & telecom

24/7

Cooling Tower

Open & closed circuit cooling towers for industrial heat rejection

FRP

Professional Customization

Tailor-made solutions — from design to manufacturing, for your specific needs

CUSTOM
ISO 9001 · CE Certified

Shanghai Soouney Refrigeration Equipment Co., Ltd.

A large-to-medium-sized high-tech enterprise integrating R&D, production and sales. Upholding "integrity, quality, service and innovation" — delivering reliable cooling solutions to the world.

11+
Export Countries
200+
Projects Delivered
19+
Years of Innovation
100%
Client Satisfaction
Custom Solutions
2007

Engineering Excellence in Refrigeration

Shanghai Soouney was founded with a vision to become a leading force in the refrigeration industry. We are China Vertical Electrical Cabinet Air Conditioner Manufacturers and Custom Vertical Electrical Cabinet Air Conditioner Suppliers. Today, we are a renowned brand in cabinet air conditioners and industrial chillers, recognised by professionals worldwide.

Rooted in the Chinese market, we provide reliable refrigeration solutions to clients across the globe — from standard products to professional customisation.

From standard products to professional customization — we deliver precision cooling.

R&D Driven

High starting points, stringent standards — continuous innovation

Integrity & Trust

Long-term partnerships built on transparency and after-sales support

Certified Quality

ISO 9001, CE, and industry-specific approvals across all lines

Global Mindset

Serving 40+ countries with tailored refrigeration solutions

"We don't just cool equipment — we build trust, one project at a time."

Why Soouney

Driven by Quality & Innovation

Committed to delivering excellence through continuous improvement and customer-centric solutions.

R&D Focus

High starting points, stringent standards — continuous product improvement

Integrity & Service

Long-term partnerships built on trust, transparency and after-sales support

Global Presence

Rooted in China, serving worldwide with reliable refrigeration solutions

Certified Quality

ISO 9001, CE, and industry-specific approvals for all product lines

Quick Inquiry